[1]王佳麗,白英麗,孫洪濤.原子吸收光譜法測(cè)定鈹中銅含量的不確定度評(píng)定[J].中國(guó)材料進(jìn)展,2021,40(07):548-552.[doi:10.7502/j.issn.1674-3962.202004001]
WANG Jiali,BAI Yingli,SUN Hongtao.Evaluation of Uncertainty in Determination of Copper in Beryllium by Atomic Absorption Spectroscopy[J].MATERIALS CHINA,2021,40(07):548-552.[doi:10.7502/j.issn.1674-3962.202004001]
點(diǎn)擊復(fù)制
原子吸收光譜法測(cè)定鈹中銅含量的不確定度評(píng)定(
)
中國(guó)材料進(jìn)展[ISSN:1674-3962/CN:61-1473/TG]
- 卷:
-
40
- 期數(shù):
-
2021年第07期
- 頁(yè)碼:
-
548-552
- 欄目:
-
- 出版日期:
-
2021-07-30
文章信息/Info
- Title:
-
Evaluation of Uncertainty in Determination of Copper in Beryllium by Atomic Absorption Spectroscopy
- 文章編號(hào):
-
1674-3962(2021)07-0548-05
- 作者:
-
王佳麗; 白英麗; 孫洪濤
-
(西北稀有金屬材料研究院寧夏有限公司 稀有金屬特種材料國(guó)家重點(diǎn)實(shí)驗(yàn)室,寧夏 石嘴山市 753000)
- Author(s):
-
WANG Jiali; BAI Yingli; SUN Hongtao
-
(State Key Laboratory of Special Rare Metal Materials, Northwest Rare Metal Materials Research Institute Ningxia Co., Ltd., Shizuishan 753000, China)
-
- 關(guān)鍵詞:
-
原子吸收光譜法; 鈹; 銅; 測(cè)量不確定度
- Keywords:
-
atomic absorption spectroscopy; beryllium; copper; measurement uncertainty
- 分類號(hào):
-
TG146.24;O657.31
- DOI:
-
10.7502/j.issn.1674-3962.202004001
- 文獻(xiàn)標(biāo)志碼:
-
A
- 摘要:
-
采用原子吸收光譜法對(duì)鈹中銅元素含量進(jìn)行測(cè)定,分析了影響測(cè)量不確定度的主要因素,通過(guò)建立測(cè)量過(guò)程中各分量不確定度評(píng)價(jià)的數(shù)學(xué)模型,對(duì)試料稱量、溶解、萃取、標(biāo)準(zhǔn)溶液配制、工作曲線擬合、樣品重復(fù)性測(cè)量等影響不確定度的分量進(jìn)行分析,最終合成得到了測(cè)量結(jié)果的擴(kuò)展不確定度。結(jié)果表明,樣品重復(fù)性測(cè)量、工作曲線擬合是影響原子吸收光譜法不確定度的主要因素,從而為采用原子吸收光譜法測(cè)定鈹中銅含量的檢測(cè)質(zhì)量控制提供理論基礎(chǔ)。
- Abstract:
-
The content of copper element in beryllium is measured by atomic absorption spectroscopy, the main sources that affect the uncertainty of measurement are analyzed, by establishing a mathematical model of each component in the measurement process. Uncertainty components including the sample weighing, dissolution, extraction, preparation of standard solution, work curve fitting and sample repeat determination are analyzed, the expanded uncertainty is got. The results show that the sample repeat determination and work curve are the main factors affecting the uncertainty of the method, which provides a theoretical basis for the determination quality control of copper content in beryllium by atomic absorption spectroscopy method.
備注/Memo
- 備注/Memo:
-
收稿日期:2020-04-03修回日期:2020-05-22 第一作者:王佳麗,女,1986年生,助理工程師通訊作者:白英麗,女,1976年生,工程師,Email: baiyingli1976@163.com